FXJ-5050TQ Automatic Folding Carton Sealing Machine


Troubleshooting
NO.
Symptom
Causes
Remedy
1
tape can not be cut
the blade is not sharp enough or the cutter blade with tape mucosa resulting blunt
replace or clean the blade
2
Tape care after being cut end of the phenomenon
correct insert seat is not installed , the blade springs lack of flexibility
Checking tool holder screws are loose , if necessary, add a little oil
3
tape affixed to cartons too loose
 sealing humpback extension spring is too loose , tape dispenser decreases due to multiple pasting its friction
increased seat sealing head drum pull or tighten the tension spring mounted seat belt friction pressure
4
box is blocked halfway 
round the adjusting nut transfer tape too tightly ; boxes highly improper ; or tension spring tight sealing head drum seat
for the tape wheel adjustment nut loosen ; re- adjust the height ; or decrease the sealing head holder elastic waist drum tension spring
5
In the sealing tape broke when
blade too prominent
lower blade position
6
boxes protruding before sealing , sealing after prop tail phenomenon
position when the artificial advance box
Incorrect
box in the right position to promote
7
lifting cylinder malfunctions or no action
or the corresponding cylinder pressure is low
Solenoid valve
adjustment or repair gas cylinder aspirant corresponding solenoid valve
8
 width adjustment cylinder malfunctions or no action
or the corresponding cylinder pressure is low
Solenoid valve
adjustment or repair gas cylinder aspirant corresponding solenoid valve
9
Front Fold front cylinder mechanism malfunctions or no action
or the corresponding cylinder pressure is low
Solenoid valve
adjustment or repair gas cylinder aspirant corresponding solenoid valve
10
before the end of the cylinder fold mechanism malfunctions or no action
or the corresponding cylinder pressure is low
Solenoid valve
adjustment or repair gas cylinder aspirant corresponding solenoid valve
11
Front Fold rear cylinder body malfunctions or no action
or the corresponding cylinder pressure is low
Solenoid valve
adjustment or repair gas cylinder aspirant corresponding solenoid valve