DZ-S series double chamber vacuum packaging machine malfunction causes and remedy

1、the whole Troubles

Symptom  CauseSolution
Machine does not work,
Control panel does not show
Not connected to powerthe power plug into a wall outlet
The main circuit fuse burnedReplace the fuse (to ensure correct specifications)
Loosening of the power switch contactsCheck, tighten, repair or replacement
Control panel is open, the machine does not workVacuum chamber lid micro switch position is incorrect or corrupt Adjust or replace micro switch
Are setting the parametercomplete parameter settings
Machine internal faultcontact the manufacturer or supplier
Vacuum chamber cover does not automatically open thegas springs or tension springs failinspection, repair or replace
Can not achieve ultimate vacuum, vacuum machine is very slowPump running in the wrong direction纠corrective steering (three phase power)
Vacuum time is set too short to extend the vacuum time
Of oil in the vacuum pump is not enough,
Oil is not clean
check the oil level, fuel or oil (note the oil type and oil)
Pipe leakReplacing
Pipe joints loosechecks and tight coupling.
Bag or cylinder leak Check and tighten hoop
Leakage, seal wearreplace the seals
Oil mist filter is saturatedReplacing the oil mist filter
Can not be sealed
Or a bad seal
The bag is not properly placed above the heating plate,the bag neatly placed on a hot plate
Sealing time is too long or too short.Shorten or lengthen the sealing time
"Heating temperature inappropriate choiceselect the appropriate heating temperature
"Damage or sticky silicone foreign bodyclean-up, replacement silicone rubber
"Linoleum is damaged or a foreign body stuckclean, replace linoleum
Inside pocket is not clean enoughclean pocket
Not inflatable
Or inflated adverse
(If there is)
Inflation time is too short or too long to shorten or lengthen the time inflation
Cylinders are empty or nearly emptyCylinders are empty or nearly empty
replacement cylinders
Cylinders is not open
to open the valve
Inflation pressure setting error检"Check whether the pressure gauge or secondary to an atmospheric pressure (1-AT0).
Alert! Mixed gas pressure at any time can not exceed 1 atm.
Vacuum chamber vacuum residual gas is normal but the bag is alwaysbad heating plate reset
Heating plate with silicone strip spacing is too large or too small
repair to the reset and flexible.
Adjust spacing.

2, the vacuum pump failure and troubleshooting

SymptomCauseSolution
Pump starting current or operating current is too largePump oil or oil overfilled wrong typecheck the oil level or oil type
The temperature is low, the oil viscosity is too highReplacing suitable vacuum pump oil
"Exhaust filter cloggingClean or replace the filter
Pump is running when the temperature is too high pumping too much or too littlecheck and adjust the oil level

Heat badClean pump and motor heat sink to improve the environment ventilation.
Unusual noises pump in operationTransmission Parts badly worn or loose ""to identify and timely repair of defective parts

Pump running in the wrong directioncorrective steering (three phase power)
Smoke or exhaust vents
Droplets
Pumping too muchlet go too much pump oil

Exhaust filter installed malposition or material ruptureReinstall or replace the exhaust filter

Exhaust filter cloggingClean or replace the filter

3, the solenoid valve failure and troubleshooting

Symptom CauseSolution
Poor sealingSealing area with dirt attached to theClear
Sealing surface is damagedFix or replace
"Rubber seal damageReplacement
Solenoid valve can not hoist or hoist is not flexibleControl fuse burned out
 "
     
Replacement
Wire badrepair
Rectifier diode breakdownReplacement
Coil burnedReplacement
Armature lifting parts of dirtReplacement
Rusted or broken springs stuckReplacement
Voltage is too lowCheck the supply voltage

4, the sealing device failure and troubleshooting

Symptom CauseSolution
Can not be sealedHeating temperature is not selected, """ ""Replacement
"""
select the appropriate heating temperature
Sealing time is too long or too short to shorten or extend the sealing time
Vacuum sealing does not meet begantest can not be greater than 0.06Mpa vacuum
Electric flat wire damageReplacement
Heating transformer damageReplacement
Sealing contactor faultrepair or replace
Sealing solenoid valve failurerepair or replace
Heat seal stuck without actionrepair
Sealing badDamage or sticky silicone foreign bodyclean-up, replacement silicone rubber
Linoleum is damaged or a foreign body stuckclean, replace linoleum
Inside pocket is not clean enoughclean pocket
"Electric flat wire loosetighten
冷Cooling time is too short long tone
Improper temperature selectionselect the appropriate temperature